MB-86N EIGörsel
Door and Window MB-86N EI

EI30 Fire Resistant Window, Door and Partition Systems; EI60 Fire Resistant Doors

MB-86N EI system is a comprehensive solution developed for thermally insulated, fire-resistant windows, doors and partition walls and is designed to be used in external fire partitions.

Water Tightness
Class E 1500 Pa | EN 12208
Thermal Performance
Uw from 0.86 W/(m²K)
Air Permeability
Class 4 | EN 12207
Fire Resistance
Class EI30 | EN 13501-2:2016-07
Exterior DoorExterior Partition SystemsSound Insulationpops upEI 15EI 30E1 60
CERTIFICATES
itb
GENERAL INFORMATION

Sistem Hakkında

MB-86N EI system is a comprehensive solution developed for heat-insulated, fire-resistant windows, doors and partition walls, and provides protection against external fires. It is designed to be used in compartments. System; It allows the creation of opening windows, doors and fixed glass partitions. According to PN-EN 13501-2 standard, it offers fire resistance classes of EI30, EW30 and EI15, and for doors up to EI60.

The system developed based on the MB-86N platform; It combines high heat and sound insulation with superior air and water tightness performance.

MB-86N EI integrates the advantages of a standard window and door system with the special performance features of fire-resistant partitions. It provides high performance in terms of thermal insulation, durability, ease of use and production technology. Applications implemented with the system offer a high level of fire safety, especially while meeting the requirements of applicable regulations and standards regarding energy efficiency and environmental protection. The system is classified as not contributing to the spread of fire (NRO)

Main Advantages of MB-86N EI System

  • Üç Chambered aluminum profiles:Have a central insulation chamber positioned between 43 or 42 mm wide heat barriers.
  • For aluminum profiles There are fire insulation elements in the rooms. Special accessories and insulation materials are used in profile and glass combinations.

EI2 class doors, fire insulation fillings are needed in profile rooms. inaudible. This feature provides faster prefabrication and lower system costs. In glazed facade applications, insulation fillings are required in the frame and registration profiles.Thanks to the wide range of glass thickness options,measured glass. Different insulating glass units can be used, including insulating glass.MB-86N EI windows come standard with RC2 class burglar-resistant hardware

TECHNICAL DETAILS
Water Tightness
Class E 1500 Pa | EN 12208
Thermal Performance
Uw from 0.86 W/(m²K)
Air Permeability
Class 4 | EN 12207
Fire Resistance
Class EI30 | EN 13501-2:2016-07